Overview
The Truck Master Series – Liquid Ring Pumps are the only safe option for pumping hydrocarbons and other flammable or hazardous materials due to the impeller operating in an intermediate fluid. These pumps also offer high airflow with very low noise levels.
The TM3 liquid ring vacuum pump performs best with 4″ hoses. 2” and 3” hoses can be used with reduced RPMs, and hoses larger than 4” can be used, but this is recommended for fluids only.
- Max RPM: 1800
- CFM: 483
- BHP Requirement at Max Pressure: 36
- Noise Level @ 23ft: 63 db(A)
- Water Consumption: 0.01 GAL/h at 68°F @ 80% Vacuum
- Weight: 216 lbs
- 27 in-Hg Continuous Operation
Features
- Ex Zone 1
- Low Noise
- High Resistance to Corrosion
- Zero Emissions
- Zero Risk of Spark
- Low Maintenance
- Integrated Water Systems
Documentation
Application Performance
Suction Hose | Vacuum-Lift Fluids | Air-lift Fluids | Air-lift Solids |
2″ | 1000 RPM | 1000 RPM | 1000 RPM |
3″ | 1000 RPM | 1100 RPM | 1600 RPM |
4″ | 1000 RPM | ||
5″ | 1000 RPM | ||
6″ | 1000 RPM |
The TM3 has its best performance in 3″ suction hoses and secondary in 2″ with reduced RPMs. For hoses above 3″ we recommend this pump for vacuum lifts of fluids only.
Vacuum Performance
Speed | CFM | HP | Lbs *ft |
1800 RPM | 483 | 36 | 106 |
1700 RPM | 454 | 34 | 104 |
1600 RPM | 430 | 30 | 97 |
1500 RPM | 395 | 27 | 94 |
1400 RPM | 371 | 23 | 86 |
1300 RPM | 330 | 20 | 81 |
1200 RPM | 297 | 19 | 82 |
Water Consumption
Temperature | 50% Vacuum | 70% Vacuum | 80% Vacuum |
68°F | 0.3 | 0.2 | 0.1 |
86°F | 0.5 | 0.3 | 0.2 |
104°F | 0.8 | 0.5 | 0.3 |
122°F | 1.4 | 0.8 | 0.6 |
131°F | 1.8 | 1.1 | 0.7 |
Gal/h
Related Packages